To contact us for more information on this product click here >>

  • Description

    Duranar liquid extrusion and coil coatings are available in a vibrant palette of solid, metallic and mica formulations that add exceptional durability to architectural metals. One of the most trusted architectural products, these coatings have protected buildings of distinction around the world for over 50 years.

  • Chemistry

    Fluoropolymer (70% PVDF + 30% Acrylic)

  • Benefits

    • Outstanding UV durability, color and chalk resistance
    • Superior corrosion resistance
    • Touch-up ability
    • Mica formulation option (Sunstorm) for pearlescent /metalescent finish
    • XL formulation provides additional coats for corrosion and stain protection
  • Suggested End Uses

    • Building panels
    • High-end storefronts
    • Curtain walls
    • Roof panels

Technical Properties

Test table / real data
Property Standard Results: Aluminum substrate Results: Coated steel substrate
Dry Film Thickness ASTM D1400 0.20-0.30 mil primer
0.70-0.80 mil color/metallic
0.30-0.40 mil clear topcoat
0.20 mil primer
0.75 mil barrier
0.75 mil color/metallic
0.50 mil clear topcoat
Gloss ASTM D523 60°: 25-35; 85°: <10 60°: 25-35; 85°: <10
Pencil Hardness ASTM D3363 F min - 2H F min - 2H
Cross Hatch Adhesion (Dry, Wet & Boiling Water) ASTM D3359 No adhesion loss No adhesion loss
Direct Impact - - -
Reverse Impact ASTM D2794: 1.5 x metal thickness (aluminum); 3.0 x metal thickness (coated steel) No cracking or adhesion loss No cracking or adhesion loss
Salt Spray Resistance ASTM B117: 5% salt fog @ 95˚F / 35˚C None or few #8 blisters; > 1/16” scribe creep average; Passes 4,000 hrs None or few #8 blisters; > 1/16” scribe creep average; Passes 1,000 hrs.
Humidity Resistance ASTM D714, ASTM D2247: 100% relative humidity @ 95˚ F / 35˚C Passes 4,000 hrs; None or few #8 blisters Passes 1,500 hrs; None or few #8 blisters
Exterior Exposure (10 Years @ 45° South Florida) ASTM D2244, ASTM D4214 Max. 5 fade; Max. 8 chalk Max. 5 fade; Max. 8 chalk
Acid Resistance ASTM D1308: 10% muriatic acid – 24 hours; 20% sulfuric acid – 18 hours No effect No effect
Acid Rain Test Kesternich SO2, DIN 50018 15 cycles minimum; No objectionable changes 15 cycles minimum; No objectionable changes
Alkali Resistance ASTM D1308: 10%, 20% NaOH, 1 hour No effect No effect